Journal of Vascular Surgery
Volume 53, Issue 2 , Pages 493-499 , February 2011

Clinical applications of robotic technology in vascular and endovascular surgery

Received 16 March 2010 ,Accepted 15 June 2010.

References 

  1. Howe RD, Matsuoka Y. Robotics for surgery. Annu Rev Biomed Eng. 1999;1:211–240
  2. Lanfranco AR, Castellanos AE, Desai JP, Meyers WC. Robotic surgery: a current perspective. Ann Surg. 2004;239:14–21
  3. Camarillo DB, Krummel TM, Salisbury JK. Robotic technology in surgery: past, present, and future. Am J Surg. 2004;188(4A Suppl):2S–15S
  4. Ruurda JP, van Vroonhoven TJ, Broeders IA. Robot-assisted surgical systems: a new era in laparoscopic surgery. Ann R Coll Surg Engl. 2002;84:223–226
  5. Hanly EJ, Talamini MA. Robotic abdominal surgery. Am J Surg. 2004;188(4A Suppl):19S–26S
  6. Nio D, Diks J, Bemelman WA, Wisselink W, Legemate DA. Laparoscopic vascular surgery: a systematic review. Eur J Vasc Endovasc Surg. 2007;33:263–271
  7. Rouers A, Meurisse N, Lavigne JP, Francart D, Quaniers J, Desiron Q, et al. Potential benefits of laparoscopic aorto-bifemoral bypass surgery. Acta Chir Belg. 2005;105:610–615
  8. Ludemann R, Swanström LL. Totally laparoscopic abdominal aortic aneurysm repair. Semin Laparosc Surg. 1999;6:153–163
  9. Lovegrove RE, Javid M, Magee TR, Galland RB. A meta-analysis of 21,178 patients undergoing open or endovascular repair of abdominal aortic aneurysm. Br J Surg. 2008;95:677–684
  10. Martinez BD, Wiegand CS. Robotics in vascular surgery. Am J Surg. 2004;188(4A Suppl):57S–62S
  11. Kanagaratnam P, Koa-Wing M, Wallace DT, Goldenberg AS, Peters NS, Davies DW. Experience of robotic catheter ablation in humans using a novel remotely steerable catheter sheath. J Interv Card Electrophysiol. 2008;21:19–26
  12. Riga C, Bicknell C, Cheshire N, Hamady M. Initial clinical application of a robotically steerable catheter system in endovascular aneurysm repair. J Endovasc Ther. 2009;16:149–153
  13. Kim HL, Schulam P. The PAKY, HERMES, AESOP, ZEUS, and da Vinci robotic systems. Urol Clin North Am. 2004;31:659–669
  14. Chun KR, Schmidt B, Köktürk B, Tilz R, Fürnkranz A, Konstantinidou M, et al. Catheter ablation - new developments in robotics. Herz. 2008;33:586–589
  15. Thal SG, Marrouche NF. Novel applications in catheter ablation. J Interv Card Electrophysiol. 2005;13(Suppl 1):17–21
  16. Da L, Zhang D, Wang T. Overview of the vascular interventional robot. Int J Med Robot. 2008;4:289–294
  17. Fu Y, Liu H, Huang W, Wang S, Liang Z. Steerable catheters in minimally invasive vascular surgery. Int J Med Robot. 2009;5:381–391
  18. Ernst S. Robotic approach to catheter ablation. Curr Opin Cardiol. 2008;23:28–31
  19. http://www.stereotaxis.com/index.phpAccessed August 16, 2010
  20. http://www.hansenmedical.com/Accessed August 16, 2010
  21. Wisselink W, Cuesta MA, Gracia C, Rauwerda JA. Robot-assisted laparoscopic aortobifemoral bypass for aortoiliac occlusive disease: a report of two cases. J Vasc Surg. 2002;36:1079–1082
  22. Stádler P. Role of the robot in totally laparoscopic aortic repair for occlusive and aneurysmal disease. Acta Chir Belg. 2009;109:300–305
  23. Stádler P, Dvorácek L, Vitásek P, Matous P. Is robotic surgery appropriate for vascular procedures? (Report of 100 aortoiliac cases). Eur J Vasc Endovasc Surg. 2008;36:401–404
  24. Diks J, Nio D, Jongkind V, Cuesta MA, Rauwerda JA, Wisselink W. Robot-assisted laparoscopic surgery of the infrarenal aorta: the early learning curve. Surg Endosc. 2007;21:1760–1763
  25. Stádler P, Matous P, Vitásek P, Spacek M. Robot-assisted aortoiliac reconstruction: a review of 30 cases. J Vasc Surg. 2006;44:915–919
  26. Nio D, Diks J, Linsen MA, Cuesta MA, Gracia C, Rauwerda JA, et al. Robot-assisted laparoscopic aortobifemoral bypass for aortoiliac occlusive disease: early clinical experience. Eur J Vasc Endovasc Surg. 2005;29:586–590
  27. Desgranges P, Bourriez A, Javerliat I, Van Laere O, Losy F, Lobontiu A, et al. Robotically assisted aorto-femoral bypass grafting: lessons learned from our initial experience. Eur J Vasc Endovasc Surg. 2004;27:507–511
  28. Kolvenbach R, Schwierz E, Wasilljew S, Miloud A, Puerschel A, Pinter L. Total laparoscopically and robotically assisted aortic aneurysm surgery: a critical evaluation. J Vasc Surg. 2004;39:771–776
  29. Killewich LA, Cindrick-Pounds LL, Gomez G. Robot-assisted laparoscopic aortic reconstruction for occlusive disease-a case report. Vasc Endovascular Surg. 2004;38:83–87
  30. Lin JC, Reddy DJ, Eun D, Fumo M, Menon M. Robotic-assisted laparoscopic dissection of the infrarenal aorta and iliac artery: a technical description and early results. Ann Vasc Surg. 2009;23:298–302
  31. Wu T, Prema J, Zagaja G, Shalhav A, Bassiouny HS. Total laparorobotic repair of abdominal aortic aneurysm with sac exclusion obliteration and aortobifemoral bypass. Ann Vasc Surg. 2009;23:686.e11–686.e16
  32. Luke P, Knudsen BE, Nguan CY, Pautler SE, Swinnimer S, Kiaii R, et al. Robot-assisted laparoscopic renal artery aneurysm reconstruction. J Vasc Surg. 2006;44:651–653
  33. Pietrabissa A, Morelli L, Ferrari M, Peri A, Ferrari V, Moglia A, et al. Mixed reality for robotic treatment of a splenic artery aneurysm. Surg Endosc. 2010;24:1204
  34. Lin JC, Eun D, Shrivastava A, Shepard AD, Reddy DJ. Total robotic ligation of inferior mesenteric artery for type II endoleak after endovascular aneurysm repair. Ann Vasc Surg. 2009;23:255.e19–255.e21
  35. Wahlgren CM, Skelly C, Shalhav A, Bassiouny H. Hybrid laparorobotic debranching and endovascular repair of thoracoabdominal aortic aneurysm. Ann Vasc Surg. 2008;22:285–289
  36. Ruurda JP, Wisselink W, Cuesta MA, Verhagen HJ, Broeders IA. Robot-assisted versus standard videoscopic aortic replacement (A comparative study in pigs). Eur J Vasc Endovasc Surg. 2004;27:501–506
  37. Smith JM, Hawes J, Engel AM. Replacement of the descending aorta using the daVinci surgical system in a sheep model: comparison of anastomosis techniques. Heart Surg Forum. 2005;8:E212–E215
  38. Tozzi P, Corno AF, von Segesser LK. Sutureless thoracic aorta to femoral artery bypass with robotic videoendoscopic approach: a fast track procedure. Interact Cardiovasc Thorac Surg. 2003;2:186–189
  39. Iyengar S, Gray WA. Use of magnetic guidewire navigation in the treatment of lower extremity peripheral vascular disease: report of the first human clinical experience. Catheter Cardiovasc Interv. 2009;73:739–744
  40. Saliba W, Cummings JE, Oh S, Zhang Y, Mazgalev TN, Schweikert RA, et al. Novel robotic catheter remote control system: feasibility and safety of transseptal puncture and endocardial catheter navigation. J Cardiovasc Electrophysiol. 2006;17:1102–1105
  41. Al-Ahmad A, Grossman JD, Wang PJ. Early experience with a computerized robotically controlled catheter system. J Interv Card Electrophysiol. 2005;12:199–202
  42. Saliba W, Reddy VY, Wazni O, Cummings JE, Burkhardt JD, Haissaguerre M, et al. Atrial fibrillation ablation using a robotic catheter remote control system: initial human experience and long-term follow-up results. J Am Coll Cardiol. 2008;51:2407–2411
  43. Riga CV, Bicknell CD, Wallace D, Hamady M, Cheshire N. Robot-assisted antegrade in-situ fenestrated stent grafting. Cardiovasc Intervent Radiol. 2009;32:522–524
  44. Riga CV, Cheshire NJ, Hamady MS, Bicknell CD. The role of robotic endovascular catheters in fenestrated stent grafting. J Vasc Surg. 2010;51:810–819discussion 819-20
  45. Nio D, Balm R, Maartense S, Guijt M, Bemelman WA. The efficacy of robot-assisted versus conventional laparoscopic vascular anastomoses in an experimental model. Eur J Vasc Endovasc Surg. 2004;27:283–286
  46. Nio D, Bemelman WA, Balm R, Legemate DA. Laparoscopic vascular anastomoses: does robotic (Zeus-Aesop) assistance help to overcome the learning curve?. Surg Endosc. 2005;19:1071–1076
  47. Mehrabi A, Yetimoglu CL, Nickkholgh A, Kashfi A, Kienle P, Konstantinides L, et al. Development and evaluation of a training module for the clinical introduction of the da Vinci robotic system in visceral and vascular surgery. Surg Endosc. 2006;20:1376–1382
  48. Karamanoukian RL, Bui T, McConnell MP, Evans GR, Karamanoukian HL. Transfer of training in robotic-assisted microvascular surgery. Ann Plast Surg. 2006;57:662–665

 Supported by an Imperial College Biomedical Research Centre Grant.

 Competition of interest: none.

 The editors and reviewers of this article have no relevant financial relationships to disclose per the JVS policy that requires reviewers to decline review of any manuscript for which they may have a competition of interest.

PII: S0741-5214(10)01630-7

doi: 10.1016/j.jvs.2010.06.154

Journal of Vascular Surgery
Volume 53, Issue 2 , Pages 493-499 , February 2011