« Previous
Next »
Journal of Vascular Surgery
Volume 52, Issue 2
, Pages 303-307
, August 2010
Long-term follow-up of neck expansion after endovascular aortic aneurysm repair
References
- Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial. Lancet. 2005;365:2179–2186
- Two-year outcomes after conventional or endovascular repair of abdominal aortic aneurysms. N Engl J Med. 2005;352:2398–2405
- . Endovascular vs. open repair of abdominal aortic aneurysms in the Medicare population. N Engl J Med. 2008;358:464–474
- Influence of pulmonary status and diabetes mellitus on aortic neck dilatation following endovascular repair of abdominal aortic aneurysms: a EUROSTAR report. J Endovasc Ther. 2007;14:122–129
- Predictive factors and clinical consequences of proximal aortic neck dilatation in 230 patients undergoing abdominal aorta aneurysm repair with self-expandable stent-grafts. J Vasc Surg. 2003;37:1200–1205
- Aortic neck dilatation and endograft migration are correlated with self-expanding endografts. J Endovasc Ther. 2007;14:318–323
- Aortic neck dilation after endovascular abdominal aortic aneurysm repair: should oversizing be blamed?. Ann Vasc Surg. 2006;20:338–345
- . Is neck dilatation after endovascular aneurysm repair graft dependent? (Results of 4 US Phase II trials). Vasc Endovascular Surg. 2005;39:47–54
- Evaluation of the proximal aortic neck enlargement following endovascular repair of abdominal aortic aneurysm: 3-years experience. Eur Radiol. 2003;13:1962–1971
- Aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol. 2002;13:887–892
- Size of the proximal neck in AAAs treated with balloon-expandable stent-grafts: CTA findings in mid- to long-term follow-up. J Endovasc Ther. 2009;16:696–707
- Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. 2002;35:1048–1060
- . Long-term outcome and reintervention after endovascular abdominal aortic aneurysm repair using the Zenith stent graft. J Vasc Surg. 2007;45:461–465discussion 5-6
- . Risk-adjusted outcome analysis of endovascular abdominal aortic aneurysm repair in a large population: how do stent-grafts compare?. J Endovasc Ther. 2005;12:417–429
This publication was supported by NIH/NCRR/OD UCSF-CTSI Grant Number KL2 RR024130. Its contents are the responsibility of the authors and do not necessarily represent the official views of the National Institutes of Health.
Competition of interest: Dr Chuter receives research support, travel expenses, and royalties from licensed patents from Cook Medical, the manufacturers of the Zenith stent graft.
The editors and reviewers of this article have no relevant financial relationships to disclose per the JVS policy that requires reviewers to decline review of any manuscript for which they may have a competition of interest.
PII: S0741-5214(10)00757-3
doi: 10.1016/j.jvs.2010.03.018
© 2010 Society for Vascular Surgery. All rights reserved.
« Previous
Next »
Journal of Vascular Surgery
Volume 52, Issue 2
, Pages 303-307
, August 2010
