Journal of Vascular Surgery
Volume 49, Issue 6 , Pages 1452-1458 , June 2009

Patency of infra-inguinal vein grafts – effect of intraoperative Doppler assessment and a graft surveillance program

Received 11 November 2008 ,Accepted 2 February 2009.

References 

  1. Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II). Infrainguinal revascularization. Eur J Vasc Endovasc Surg. 2007;33(Suppl 1):S57–S62
  2. Idu MM, Buth J, Hop WC, Cuypers P, van de Pavoordt ED, Tordoir JM. Factors influencing the development of vein-graft stenosis and their significance for clinical management. Eur J Vasc Endovasc Surg. 1999;17:15–21
  3. Singh N, Sidawy AN, DeZee KJ, Neville RF, Akbari C, Henderson W. Factors associated with early failure of infrainguinal lower extremity arterial bypass. J Vasc Surg. 2008;47:556–561
  4. Idu MM, Truyen E, Buth J. Surveillance of lower extremity vein grafts. Eur J Vasc Surg. 1992;6:456–462
  5. Carter A, Murphy MO, Halka AT, Turner NJ, Kirton JP, Murray D, et al. The natural history of stenoses within lower limb arterial bypass grafts using a graft surveillance program. Ann Vasc Surg. 2007;21:695–703
  6. Houghton AD, Todd C, Pardy B, Taylor PR, Reidy JF. Percutaneous angioplasty for infrainguinal graft-related stenoses. Eur J Vasc Endovasc Surg. 1997;14:380–385
  7. Mills JL, Fujitani RM, Taylor SM. Contribution of routine intraoperative completion arteriography to early infrainguinal bypass patency. Am J Surg. 1992;164:506–510discussion 510-1
  8. Miller A, Marcaccio EJ, Tannenbaum GA, Kwolek CJ, Stonebridge PA, Lavin PT, et al. Comparison of angioscopy and angiography for monitoring infrainguinal bypass vein grafts: results of a prospective randomized trial. J Vasc Surg. 1993;17:382–396discussion 396-8
  9. Rzucidlo EM, Walsh DB, Powell RJ, Zwolak RM, Fillinger MF, Schermerhorn ML, et al. Prediction of early graft failure with intraoperative completion duplex ultrasound scan. J Vasc Surg. 2002;36:975–981
  10. Dalman RL, Harris EJ, Zarins CK. Is completion arteriography mandatory after reversed-vein bypass grafting?. J Vasc Surg. 1996;23:637–644
  11. Woelfle KD, Kugelmann U, Bruijnen H, Storm G, Loeprecht H. Intraoperative imaging techniques in infrainguinal arterial bypass grafting: completion angiography versus vascular endoscopy. Eur J Vasc Surg. 1994;8:556–561
  12. Beard JD, Scott DJ, Skidmore R, Baird RN, Horrocks M. Operative assessment of femorodistal bypass grafts using a new Doppler flowmeter. Br J Surg. 1989;76:925–928
  13. Giannoukas AD, Androulakis AE, Labropoulos N, Wolfe JH. The role of surveillance after infrainguinal bypass grafting. Eur J Vasc Endovasc Surg. 1996;11:279–289
  14. Rutherford RB, Baker JD, Ernst C, Johnston KW, Porter JM, Ahn S, et al. Recommended standards for reports dealing with lower extremity ischemia: revised version. J Vasc Surg. 1997;26:517–538
  15. Papanicolaou G, Aziz I, Yellin AE, Weaver FA. Intraoperative color duplex scanning for infrainguinal vein grafts. Ann Vasc Surg. 1996;10:347–355
  16. Jagadesham VP, Snowdon S, Weston MJ, Kent PJ. Intraoperative doppler flow measurement do not predict ‘at-risk’ status of infrainguinal bypass grafts. Eur J Vasc Endovasc Surg. 2005;30:597–603
  17. Ferris BL, Mills JL, Hughes JD, Durrani T, Knox R. Is early postoperative duplex scan surveillance of leg bypass grafts clinically important?. J Vasc Surg. 2003;37:495–500
  18. Ihlberg LH, Alback NA, Lassila R, Lepantalo M. Intraoperative flow predicts the development of stenosis in infrainguinal vein grafts. J Vasc Surg. 2001;34:269–276
  19. Johnson BL, Bandyk DF, Back MR, Avino AJ, Roth SM. Intraoperative duplex monitoring of infrainguinal vein bypass procedures. J Vasc Surg. 2000;31:678–690
  20. Vos GA, Rauwerda JA, van den Broek TA, Bakker FC. The correlation of peroperative outflow resistance measurements with patency 109 infrainguinal arterial reconstructions. Eur J Vasc Surg. 1989;3:539–542
  21. Wolfle KD, Bruijnen H, Morski A, Kugelmann U, Campbell P, Loeprecht H. The importance of graft blood flow and peripheral outflow resistance for early patency in infrainguinal arterial reconstructions. Vasa. 1999;28:34–41
  22. Lundell A, Lindblad B, Bergqvist D, Hansen F. Femoropopliteal-crural graft patency is improved by an intensive surveillance program: a prospective randomized study. J Vasc Surg. 1995;21:26–33discussion 33-4
  23. Ihlberg L, Luther M, Tierala E, Lepantalo M. The utility of duplex scanning in infrainguinal vein graft surveillance: Results from a randomised controlled trial. Eur J Vasc Endovasc Surg. 1998;16:19–27
  24. Ihlberg L, Luther M, Alback A, Kantonen I, Lepantalo M. Does a completely accomplished duplex-based surveillance prevent vein-graft failure?. Eur J Vasc Endovasc Surg. 1999;18:395–400
  25. Davies AH, Hawdon AJ, Sydes MR, Thompson SG. Is duplex surveillance of value after leg vein bypass grafting? (Principal results of the Vein Graft Surveillance Randomised Trial (VGST)). Circulation. 2005;112:1985–1991

 Competition of interest: none.

PII: S0741-5214(09)00229-8

doi: 10.1016/j.jvs.2009.02.002

Journal of Vascular Surgery
Volume 49, Issue 6 , Pages 1452-1458 , June 2009