Journal of Vascular Surgery
Volume 48, Issue 2 , Pages 303-310 , August 2008

A computational fluid dynamic study of stent graft remodeling after endovascular repair of thoracic aortic dissections

Presented at the Twentieth Annual Meeting of the Western Vascular Society, Kona, Hawaii, Sep 8-11, 2007.

  • Stephen W.K. Cheng, MS

      Affiliations

    • Department of Surgery, University of Hong Kong Medical Centre, Queen Mary Hospital, The University of Hong Kong, Hong Kong, China
    • Corresponding Author InformationReprint requests: Stephen W. K. Cheng, Division of Vascular Surgery, Department of Surgery, University of Hong Kong Medical Centre, Queen Mary Hospital, Pokfulam Road, Hong Kong.
  • ,
  • Edward S.K. Lam, MPh

      Affiliations

    • Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
  • ,
  • George S.K. Fung, PhD

      Affiliations

    • Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, China.
  • ,
  • Pei Ho, MB, BS

      Affiliations

    • Department of Surgery, University of Hong Kong Medical Centre, Queen Mary Hospital, The University of Hong Kong, Hong Kong, China
  • ,
  • Albert C.W. Ting, MS

      Affiliations

    • Department of Surgery, University of Hong Kong Medical Centre, Queen Mary Hospital, The University of Hong Kong, Hong Kong, China
  • ,
  • Kwok W. Chow, BS, PhD

      Affiliations

    • Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China

Received 12 December 2007 ,Accepted 27 March 2008.

References 

  1. Liffman K, Lawrence-Brown MM, Se mmens JB, Bui A, Rudman M, Hartley DE. Analytical modeling and numerical simulation of forces in an endoluminal graft. J Endovasc Ther. 2001;8:358–371
  2. Howell BA, Kim T, Cheer A, Dwyer H, Saloner D, Chuter TA. Computational fluid dynamics within bifurcated abdominal aortic stent-grafts. J Endovasc Ther. 2007;14:138–143
  3. Kim T, Cheer AY, Dwyer HA. A simulated dye method for flow visualization with a computational model for blood flow. J Biomech. 2004;37:1125–1136
  4. Nichols WW. McDonald's blood flow in arteries : theoretical, experimental, and clinical principles. 4th ed.. London: Arnold/Oxford University Press; 1998;
  5. Pedley TJ. Mathematical modelling of arterial fluid dynamics. J Eng Math. 2003;47:419–444
  6. Fung YC. Biomechanics: circulation. 2nd ed.. New York: Springer; 1997;
  7. Morris L, Delassus P, Walsh M, McGloughlin T. A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of AAA. J Biomech. 2004;37:1087–1095
  8. Resch T, Malina M, Lindblad B, Malina J, Brunkwall J, Ivancev K. The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study. Eur J Vasc Endovasc Surg. 2000;20:190–195
  9. Shahcheraghi N, Dwyer HA, Cheer AY, Barakat AI, Rutaganira T. Unsteady and three-dimensional simulation of blood flow in the human aortic arch. J Biomech Eng. 2002;124:378–387
  10. Franzini JB. Fluid mechanics with engineering applications. New York: McGraw-Hill; 1997;
  11. Zhou SS, How TV, Rao Vallabhaneni S, Gilling-Smith GL, Brennan JA, Harris PL, et al. Comparison of the fixation strength of standard and fenestrated stent-grafts for endovascular abdominal aortic aneurysm repair. J Endovasc Ther. 2007;14:168–175
  12. Mohan IV, Harris PL, Van Marrewijk CJ, Laheij RJ, How TV. Factors and forces influencing stent-graft migration after endovascular aortic aneurysm repair. J Endovasc Ther. 2002;9:748–755
  13. Malina M, Lindblad B, Ivancev K, Lindh M, Malina J, Brunkwall J. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?. J Endovasc Surg. 1998;5:310–317
  14. Makaroun MS, Dillavou ED, Kee ST, Sicard G, Chaikof E, Bavaria J, et al. Endovascular treatment of thoracic aneurysms: results of the phase II multicenter trial of the GORE TAG thoracic endoprosthesis. J Vasc Surg. 2005;41:1–9
  15. Matsumura JS, Cambria RP, Dake MD, Moore RD, Svensson LG, Snyder S. International controlled clinical trial of thoracic endovascular aneurysm repair with the Zenith TX2 endovascular graft: 1-year results. J Vasc Surg. 2008;47:247–257
  16. O'Neill S, Greenberg RK, Resch T, Bathurst S, Fleming D, Kashyap V, et al. An evaluation of centerline of flow measurement techniques to assess migration after thoracic endovascular aneurysm repair. J Vasc Surg. 2006;43:1103–1110
  17. Muhs BE, Vincken KL, van Prehn J, Stone MKC, Bartels LW, Prokop M, et al. Dynamic Cine-CT angiography for the evaluation of the thoracic aorta; in sight in dynamic changes with implications for thoracic endograft treatment. Eur J Vasc Endovasc Surg. 2006;32:532–536

 Competition of interest: none.

PII: S0741-5214(08)00500-4

doi: 10.1016/j.jvs.2008.03.050

Journal of Vascular Surgery
Volume 48, Issue 2 , Pages 303-310 , August 2008