Journal of Vascular Surgery
Volume 46, Issue 6 , Pages 1103-1111.e2 , December 2007

Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. A study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) Registry

Presented at the Sixty-first Annual Meeting of the Society for Vascular Surgery, Baltimore, Md, Jun 7-10, 2007.

  • Jacob Buth, MD

      Affiliations

    • EUROSTAR Data Registry Center, Catharina Hospital, Eindhoven, The Netherlands
    • Corresponding Author InformationReprint requests: Jacob Buth, MD, Department of Surgery, Catharina Hospital, PO Box 1350, 5602 ZA Eindhoven, The Netherlands.
  • ,
  • Peter L. Harris, MD

      Affiliations

    • EUROSTAR secretariat, Royal Liverpool and University Hospital, Liverpool, United Kingdom
  • ,
  • Roel Hobo, MSc

      Affiliations

    • EUROSTAR Data Registry Center, Catharina Hospital, Eindhoven, The Netherlands
  • ,
  • Randolph van Eps, MD

      Affiliations

    • Department of Surgery, Catharina Hospital, Eindhoven, The Netherlands
  • ,
  • Philippe Cuypers, MD

      Affiliations

    • Department of Surgery, Catharina Hospital, Eindhoven, The Netherlands
  • ,
  • Lucien Duijm, MD

      Affiliations

    • Department of Radiology, Catharina Hospital, Eindhoven, The Netherlands.
  • ,
  • Xander Tielbeek, MD

      Affiliations

    • Department of Radiology, Catharina Hospital, Eindhoven, The Netherlands.

Received 21 June 2007 ,Accepted 10 August 2007.

References 

  1. Hamerlijnck R, De Geest R, Brutel de la Riviere A, Defauw J, Knaepen P, Vermeulen F. Surgical correction of descending thoracic aortic aneurysms with shunt or bypass techniques versus simple aortic cross-clamping. Eur J Cardiothorac Surg. 1989;3:37–42
  2. Svensson LG, Crawford ES, Hess KR, Coselli JS, Safi HJ. Variables predictive of outcome in 832 patients undergoing repairs of the descending thoracic aorta. Chest. 1993;104:1248–1253
  3. Galloway AC, Schwartz DS, Culliford AT, Ribakove GH, Grossi EA, Esposito RA, et al. Selective approach to descending thoracic aortic aneurysm repair: a ten-year experience. Ann Thorac Surg. 1996;62:1152–1157
  4. Kouchoukos NT, Dougenis D. Surgery of the thoracic aorta. N Engl J Med. 1997;336:1876–1888
  5. Dake MD, Miller DC, Mitchell RS, Semba CP, Moore KA, Sakai T. The “first generation” of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta. J Thorac Cardiovasc Surg. 1998;116:689–703
  6. Nienaber CA, Fattori R, Lund G, Dieckmann C, Wolf W, von Kodolitsch Y, et al. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement. N Engl J Med. 1999;340:1539–1545
  7. Greenberg R, Resch T, Nyman U, Lindh M, Brunkwall J, Brunkwall P, et al. Endovascular repair of descending thoracic aortic aneurysms: an early experience with intermediate-term follow-up. J Vasc Surg. 2000;31:147–156
  8. Gravereaux EC, Faries PL, Burks JA, Latessa V, Spielvogel D, Hollier LH, et al. Risk of spinal cord ischemia after endograft repair of thoracic aortic aneurysms. J Vasc Surg. 2001;34:997–1003
  9. Bell RE, Taylor PR, Aukett M, Sabharwal T, Reidy JF. Mid-term results for second-generation thoracic stent grafts. Br J Surg. 2003;90:811–817
  10. Sullivan TM, Sundt TM. Complications of thoracic aortic endografts: spinal cord ischemia and stroke. J Vasc Surg. 2006;43(suppl A):85A–88A
  11. Leurs LJ, Bell R, Degrieck Y, Thomas S, Hobo R, Lundbom J EUROSTAR; UK Thoracic Endograft Registry collaborators. Endovascular treatment of thoracic aortic diseases: combined experience from the EUROSTAR and United Kingdom Thoracic Endograft registries. J Vasc Surg. 2004;40:670–679
  12. Chaikof EL, Blankensteijn JD, Harris PL, White GH, Zarins CK, Bernhard VM, et al. Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. 2002;35:1048–1060
  13. White RA, Donayre CE, Walot I, Lippmann M, Woody J, Lee J, et al. Endovascular exclusion of descending thoracic aortic aneurysms and chronic dissections: initial clinical results with the AneuRx device. J Vasc Surg. 2001;33:927–934
  14. Criado FJ, Clark NS, Barnatan MF. Stent graft repair in the aortic arch and descending thoracic aorta: a 4-year experience. J Vasc Surg. 2002;36:1121–1128
  15. Ellozy SH, Carroccio A, Minor M, Jacobs T, Chae K, Cha A, et al. Challenges of endovascular tube graft repair of thoracic aortic aneurysm: midterm follow-up and lessons learned. J Vasc Surg. 2003;38:676–683
  16. Lepore V, Lonn L, Delle M, Mellander S, Radberg G, Risberg B. Treatment of descending thoracic aneurysms by endovascular stent grafting. J Card Surg. 2003;18:436–443
  17. Orend KH, Scharrer-Pamler R, Kapfer X, Kotsis T, Gorich J, Sunder-Plassmann L. Endovascular treatment in diseases of the descending thoracic aorta: 6-year results of a single center. J Vasc Surg. 2003;37:91–99
  18. Stone DH, Brewster DC, Kwolek CJ, Lamuraglia GM, Conrad MF, Chung TK, et al. Stent-graft versus open-surgical repair of the thoracic aorta: mid-term results. J Vasc Surg. 2006;44:1188–1197
  19. Fattori R, Nienaber CA, Rousseau H, Beregi JP, Heijmen R, Grabenwoger M, et al. Results of endovascular repair of the thoracic aorta with the Talent Thoracic stent graft: the Talent Thoracic Retrospective Registry. J Thorac Cardiovasc Surg. 2006;132:332–339
  20. Marcheix B, Dambrin C, Bolduc JP, Arnaud C, Cron C, Hollington L, et al. Midterm results of endovascular treatment of atherosclerotic aneurysms of the descending thoracic aorta. J Thorac Cardiovasc Surg. 2006;132:1030–1036
  21. Bavaria JE, Appoo JJ, Makaroun MS, Verter J, Yu ZF, Mitchell RS Gore TAG Investigators. Endovascular stent grafting versus open surgical repair of descending thoracic aortic aneurysms in low-risk patients: a multicenter comparative trial. J Thorac Cardiovasc Surg. 2007;133:369–377
  22. Baum RA, Stavropoulos SW, Fairman RM, Carpenter JP. Endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol. 2003;14:1111–1117
  23. Grabenwoger M, Fleck T, Ehrlich M, Czerny M, Hutschala D, Schoder M, et al. Secondary surgical interventions after endovascular stent-grafting of the thoracic aorta. Eur J Cardiothorac Surg. 2004;26:608–613
  24. Matsumura JS. Worldwide survey of thoracic endografts: practical clinical application. J Vasc Surg. 2006;43(suppl A):20A–21A
  25. Safi HJ, Miller CC, Carr C, Iliopoulos DC, Dorsay DA, Baldwin JC. Importance of intercostal artery reattachment during thoracoabdominal aortic aneurysm repair. J Vasc Surg. 1998;27:58–66
  26. Coselli JS, LeMaire SA, Miller CC, Schmittling ZC, Koksoy C, Pagan J, et al. Mortality and paraplegia after thoracoabdominal aortic aneurysm repair: a risk factor analysis. Ann Thorac Surg. 2000;69:409–414
  27. Cambria RP, Clouse WD, Davison JK, Dunn PF, Corey M, Dorer D. Thoracoabdominal aneurysm repair: results with 337 operations performed over a 15-year interval. Ann Surg. 2002;236:471–479
  28. Chiesa R, Melissano G, Civilini E, de Moura ML, Carozzo A, Zangrillo A. Ten years experience of thoracic and thoracoabdominal aortic aneurysm surgical repair: lessons learned. Ann Vasc Surg. 2004;18:514–520
  29. Wan IY, Angelini GD, Bryan AJ, Ryder I, Underwood MJ. Prevention of spinal cord ischaemia during descending thoracic and thoracoabdominal aortic surgery. Eur J Cardiothorac Surg. 2001;19:203–213
  30. Safi HJ, Hess KR, Randel M, Iliopoulos DC, Baldwin JC, Mootha RK, et al. Cerebrospinal fluid drainage and distal aortic perfusion: reducing neurologic complications in repair of thoracoabdominal aortic aneurysm types I and II. J Vasc Surg. 1996;23:223–228
  31. Guerit JM, Witdoeckt C, Verhelst R, Matta AJ, Jacquet LM, Dion RA. Sensitivity, specificity, and surgical impact of somatosensory evoked potentials in descending aorta surgery. Ann Thorac Surg. 1999;67:1943–1946
  32. Jacobs MJ, Meylaerts SA, de Haan P, de Mol BA, Kalkman CJ. Strategies to prevent neurologic deficit based on motor-evoked potentials in type I and II thoracoabdominal aortic aneurysm repair. J Vasc Surg. 1999;29:48–57
  33. Kieffer E, Fukui S, Chiras J, Koskas F, Bahnini A, Cormier E. Spinal cord arteriography: a safe adjunct before descending thoracic or thoracoabdominal aortic aneurysmectomy. J Vasc Surg. 2002;35:262–268
  34. Cambria RP, Brewster DC, Lauterbach SR, Kaufman JL, Geller S, Fan CM, et al. Evolving experience with thoracic aortic stent graft repair. J Vasc Surg. 2002;35:1129–1136
  35. Makaroun MS, Dillavou ED, Kee ST, Sicard G, Chaikof E, Bavaria J, et al. Endovascular treatment of thoracic aortic aneurysms: results of the phase II multicenter trial of the GORE TAG thoracic endoprosthesis. J Vasc Surg. 2005;41:1–9
  36. Mitchell RS, Miller DC, Dake MD. Stent-graft repair of thoracic aortic aneurysms. Semin Vasc Surg. 1997;10:257–271
  37. Chiesa R, Melissano G, Marrocco-Trischitta MM, Civilini E, Setacci F. Spinal cord ischemia after elective stent-graft repair of the thoracic aorta. J Vasc Surg. 2005;42:11–17
  38. Khoynezhad A, Donayre CE, Bui H, Kopchok GE, Walot I, White RA. Risk factors of neurologic deficit after thoracic aortic endografting. Ann Thorac Surg. 2007;83:882–889
  39. Grabenwoger M, Hutschala D, Ehrlich MP, Cartes-Zumelzu F, Thurnher S, Lammer J, et al. Thoracic aortic aneurysms: treatment with endovascular self-expandable stent grafts. Ann Thorac Surg. 2000;69:441–445
  40. Gorich J, Asquan Y, Seifarth H, Kramer S, Kapfer X, Orend KH, et al. Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther. 2002;9(Suppl 2):II39–II43
  41. Riesenman PJ, Farber MA, Mendes RR, Marston WA, Fulton JJ, Keagy BA. Coverage of the left subclavian artery during thoracic endovascular aortic repair. J Vasc Surg. 2007;45:90–94
  42. Lambrechts D, Casselman F, Schroeyers P, De Geest R, D’Haenens P, Degrieck I. Endovascular treatment of the descending thoracic aorta. Eur J Vasc Endovasc Surg. 2003;26:437–444
  43. Rehders TC, Petzsch M, Ince H, Kische S, Korber T, Koschyk DH, et al. Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: risk and relevance. J Endovasc Ther. 2004;11:659–666
  44. Peterson BG, Eskandari MK, Gleason TG, Morasch MD. Utility of left subclavian artery revascularization in association with endoluminal repair of acute and chronic thoracic aortic pathology. J Vasc Surg. 2006;43:433–439
  45. McWilliams RG, Murphy M, Hartley D, Lawrence-Brown MM, Harris PL. In situ stent-graft fenestration to preserve the left subclavian artery. J Endovasc Ther. 2004;11:170–174
  46. Saito N, Kimura T, Odashiro K, Toma M, Nobuyoshi M, Ueno K, et al. Feasibility of the Inoue single-branched stent-graft implantation for thoracic aortic aneurysm or dissection involving the left subclavian artery: short- to medium-term results in 17 patients. J Vasc Surg. 2005;41:206–212
  47. Parlani G, Verzini F, Zannetti S, De Rango P, Lenti M, Lupattelli L, et al. Does gender influence outcome of AAA endoluminal repair?. Eur J Vasc Endovasc Surg. 2003;26:69–73erratum in: Eur J Vasc Endovasc Surg 2003;26:680

 Competition of interest: none.

 Additional material for this article may be found online at www.jvascsurg.org.

 CME article

PII: S0741-5214(07)01348-1

doi: 10.1016/j.jvs.2007.08.020

Journal of Vascular Surgery
Volume 46, Issue 6 , Pages 1103-1111.e2 , December 2007