« Previous
Next »
Journal of Vascular Surgery
Volume 44, Issue 4
, Pages 694-700
, October 2006
Sac behavior after aneurysm treatment with the Gore Excluder low-permeability aortic endoprosthesis: 12-month comparison to the original Excluder device
References
- . Abdominal aortic aneurysm repair devices . Expert Rev Med Devices . 2006;3:185–194
- Variable sac behavior after endovascular repair of abdominal aortic aneurysm: analysis of core laboratory data . J Vasc Surg . 2004;39:95–101
- . Differing morphological changes following endovascular AAA repair using balloon-expandable or self-expanding endografts . J Endovasc Ther . 2000;7:479–485
- Endovascular repair of abdominal aortic aneurysms: device-specific outcome . J Vasc Surg . 2003;37:991–998
- Abdominal aortic aneurysm size regression after endovascular repair is endograft dependent . J Vasc Surg . 2003;37:716–723
-
Gore Excluder bifurcated endoprosthesis annual clinical update
. Flagstaff (AZ): W. L. Gore & Associates Inc; 2006;
- . Late abdominal aortic aneurysm enlargement after endovascular repair with the Excluder device . J Vasc Surg . 2004;39:1236–1241
- . What are the causes of endotension? . J Endovasc Ther . 2001;8:454–456
- Delayed aortic aneurysm enlargement due to endotension after endovascular abdominal aortic aneurysm repair . J Vasc Surg . 2003;38:840–842
- . Aneurysm sac hygroma: a cause of endotension . J Endovasc Ther . 2001;8:447–453
- . Long-term fate of the aneurysmal sac after endoluminal exclusion of abdominal aortic aneurysms . J Vasc Surg . 2000;32:689–696
- Reporting standards for endovascular aortic aneurysm repair . J Vasc Surg . 2002;35:1048–1060
- . Two-dimensional versus three-dimensional CT scan for aortic measurement . J Endovasc Ther . 2003;10:531–538
- . Midterm clinical success and behavior of the aneurysm sac after endovascular AAA repair with the Excluder graft . J Vasc Surg . 2005;42:1052–1057
- . A multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysm . J Vasc Surg . 2003;37:262–271
- . Three-dimensional analysis of enlarging aneurysms after endovascular abdominal aortic aneurysm repair in the Gore Excluder Pivotal clinical trial . J Vasc Surg . 2006;43:888–895
-
.
Zenith AAA endovascular graft: intermediate-term results of the US multicenter trial
.
J Vasc Surg
. 2004;39:I209–I218
- An update of the Zenith endovascular graft for abdominal aortic aneurysms: initial implantation and mid-term follow-up data . J Vasc Surg . 2001;33:S157–S164
- . Midterm results of a second generation bifurcated endovascular graft for abdominal aortic aneurysm repair: the French Vanguard trial . J Vasc Surg . 1999;30:209–218
Competition of interest: Drs Eskandari, Matsumura, and Morasch serve as consultants to W. L. Gore & Associates, Inc, and are on their speakers’ bureau. Dr Morasch receives research support from W. L. Gore & Associates. Dr Makaroun has a consulting agreement with W. L. Gore & Associates and receives research support from them.An earlier version of this manuscript was presented in the poster session at the Society for Clinical Vascular Surgery Thirty-fourth Annual Symposium, Las Vegas, NV, March 8-11, 2006.
PII: S0741-5214(06)01123-2
doi: 10.1016/j.jvs.2006.06.018
© 2006 The Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Vascular Surgery
Volume 44, Issue 4
, Pages 694-700
, October 2006
