« Previous
Next »
Journal of Vascular Surgery
Volume 39, Issue 1
, Pages 20-26
, January 2004
Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the zenith multicenter trial
References
- . Risk factors for endoleak and the evidence for stent-graft oversizing in patients undergoing endovascular aneurysm repair. Eur J Vasc Endovasc Surg. 2001;21:344–349
- . Challenges in stent grafting (dealing with difficult neck and iliac artery anatomy). Perspect Vasc Surg Endovasc Ther. 2001;14:41–56
- . Endograft migration 1-4 years after endovascular AAA repair with the AneuRx device (a cautionary note). J Vasc Surg. 2002;36:476–484
-
Greenberg RK, Chuter TAM, Sternbergh WC III, for the Zenith investigators. The Zenith endovascular graft: results of the United States multicenter trial. J Vasc Surg (in review)
- Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. 2002;35:1048–1060
- Abdominal aortic aneurysm repair with the Zenith stent graft (short to midterm results). J Vasc Surg. 2002;36:217–225
- . The Zenith Aortic Stent-graft (a 5-year single-center experience). J Endovasc Ther. 2002;9:719–728
- An update of the Zenith endovascular graft for abdominal aortic aneurysms (initial implantation and mid-term follow-up data). J Vasc Surg. 2001;33:S157–164
- . The impact of stent design on proximal stent-graft fixation in the abdominal aorta (an experimental study). Eur J Vasc Endovasc Surg. 2000;20:190–195
-
Matsumura JS, Hoff FL, Pearce WH. Incidence and causes of proximal device migration after EVAR. Paper presented at: VEITH symposium; November 21, 2002; New York
- Stent-graft migration following endovascular repair of aneurysms with large proximal necks (anatomical risk factors and long-term sequeli). J Endovasc Ther. 2002;9:652–664
- . Stent attachment site-related endoleakage after stent graft treatment (an in vitro study of the effects of graft size, stent type, and atherosclerotic wall changes). J Vasc Surg. 1999;30:658–667
- . Aortic aneurysm sac shrinkage after endovascular repair is device dependent (a comparison of Zenith and AneuRx endografts). Ann Vasc Surg. 2003;17:49–53
- . Endoleak as a predictor of outcome after endovascular aneurysm repair (AneuRx multicenter clinical trial). J Vasc Surg. 2000;32:90–107
- . The US AneuRx clinical trial (6-year clinical update 2002). J Vasc Surg. 2003;37:904–908
- . A multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysms. J Vasc Surg. 2003;37:262–271
☆ All authors received research support from Cook to administer the phase II trial of the Zenith endograft. RKG and TAMC are consultants for Cook Inc.
PII: S0741-5214(03)01385-5
doi: 10.1016/j.jvs.2003.09.022
© 2003 The Society for Vascular Surgery and The American Association for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Journal of Vascular Surgery
Volume 39, Issue 1
, Pages 20-26
, January 2004